Description

LHE high-efficiency air/water heat pumps are particularly suitable for applications where maximum efficiency in heating mode and a low noise level are required. The units are specifically designed to provide the best efficiency in heating mode; they can operate at outside temperatures down to -20°C and produce water up to a temperature of 60°C.
All sizes are supplied with reverse cycle valve used for winter defrost; the RV versions are also able to produce cold water in summer period (not available for HH versions).

Versions

  • HH Heating only
  • RV Reversible heating/cooling
  • HA High efficiency, AC fans
  • HE High efficiency, EC fans
  • LS Low noise
  • XL Super low noise
  • P4U 4 pipe systems heating/cooling
  • P4S 2+2 pipe systems with D.H.W. production

Refrigerants

  • R454B

Description

The LZTi series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or those applications where it is necessary to have maximum efficiency when heating.

They have been optimized on heating mode, are able to produce water up to 65°C and can operate down to -20°C ambient temperature.

LZTi units are available in 2 or 4 pipe (SW6) versions. Both versions can produce domestic hot water, in the standard LZTi through the activation of an external 3-way-valve and in the SW6 version by means of a separate heat exchanger and hydraulic circuit for the domestic hot water.

All models are supplied as standard with a reversing valve for defrost and cold water production in summer.

Versions

  • SW6 4 pipes unit capable of producing hot and cold water at the same time on two independent hydraulic circuits

Refrigerants

  • R410A

Description

The LHi P4U/P4S series high-efficiency air-to-water heat pumps are units designed for four-pipe air conditioning and heating systems, which allow the simultaneous or separate production of cold water for cooling and hot water for heating.

The units are supplied with an additional exchanger, used as a condenser for hot water, whose production is independent of the unit’s operating mode. The exchanger is automatically activated by microprocessor control when the hot water temperature on the return flow is lower than the set applied. These units are able to produce hot water and cold water simultaneously and/or separately with very high energy efficiency.

They are all supplied complete with a specific advanced microprocessor control equipped with software for the management of the various priorities.

The XL versions also have an extremely low noise level thanks to the use of a special floating vibration dampening system that allows a noise reduction of about 5-7 dB(A) (optional).

Versions

  • RV Reversible heating/cooling
  • HH Heating only
  • SE Standard efficiency, EC fans
  • LS Low noise
  • XL Super low noise
  • P4U 4 pipe systems heating/cooling
  • P4S 2+2 pipe systems with D.H.W. production

Refrigerants

  • R410A

Description

The high efficiency air / water heat pumps of the LHA series are units designed for 4-pipe air conditioning and heating systems, which allow the production of cold water for cooling and hot water for heating at the same time or separately.

The units are supplied with an additional exchanger, used as a condenser for hot water, the production of which is independent of the operation mode of the unit.
Activation of the exchanger takes place automatically via the microprocessor control when the hot water temperature on the return is lower than the set point. These units are able to produce hot water and cold water simultaneously and / or separately with very high energy efficiencies.

They are all supplied complete with a specific advanced microprocessor control provided with software for managing the various priorities.

The XL versions also have an extremely low noise level thanks to the use of a special floating vibration damping system that allows a noise reduction of about 6-8 dB (A) (optional).

Versions

  • SA Standard efficiency, AC fans
  • SE Standard efficiency, EC fans
  • HA High efficiency, AC fans
  • HE High efficiency, EC fans
  • LS Low noise
  • XL Super low noise
  • P4U 4 pipe systems heating/cooling
  • P4S 2+2 pipe systems with D.H.W. production

Refrigerants

  • R410A

Description

The high efficiency air / water heat pumps of the LZT/P4 series are units designed for 4-pipe air conditioning and heating systems, which allow the production of cold water for cooling and hot water for heating at the same time or separately.

The units are supplied with an additional exchanger, used as a condenser for hot water, the production of which is independent of the operation mode of the unit.
Activation of the exchanger takes place automatically via the microprocessor control when the hot water temperature on the return is lower than the set point. These units are able to produce hot water and cold water simultaneously and / or separately with very high energy efficiencies.

They are all supplied complete with a specific advanced microprocessor control provided with software for managing the various priorities.

The XL versions also have an extremely low noise level thanks to the use of a special floating vibration damping system that allows a noise reduction of about 6-8 dB (A) (optional).

Versions

  • SA Standard efficiency, AC fans
  • SE Standard efficiency, EC fans
  • HA High efficiency, AC fans
  • HE High efficiency, EC fans
  • LS Low noise
  • XL Super low noise
  • NN Ultra low noise
  • P4U 4 pipe systems heating/cooling
  • P4S 2+2 pipe systems with D.H.W. production

Refrigerants

  • R410A

Description

The air source high efficiency heat pumps WZT series, in the NN configuration, are particularly suitable for those applications where it is necessary to have maximum efficiency in heating mode and a noise level extremely low and, for this purpose, are provided in two sections, linked together by refrigerant lines, installing the compressor in the internal section. The units have been designed specifically to have the best possible efficiency, they may operate down to ambient temperatures of -20°C and produce hot water up to 65°C. The units are available in 2-pipe (P2S, P2U), version 2 + 2 pipe (P4S), and in version 4 pipe (P4U).
The units P2U are not able to produce sanitary hot water, the P2S versions are able to produce domestic hot water through the activation of an external 3-way valve (not supplied), while P4S versions and P4U too are able to produce hot water regardless of the mode unit is operating, through the activation of a specific refrigerating circuit. All models are equipped with reverse cycle valve for winter defrost mode, RV versions are also able to produce cold water in summer (not available for HH version).
The noise level is extremely contained thanks to the use of a special floating system vibration damping that enables a reduction in terms of noise about 6-8 db (A) of compressors side and the fans in the combination with the specific number of turns extremely low (about 450 rpm).

Versions

  • HE High efficiency, EC fans
  • NN Ultra low noise.
  • P4U 4 pipe systems heating/cooling
  • P4S 2+2 pipe systems with domestic hot water production

Refrigerants

  • R410A